Request pricing for this cell
Contact Voltaplex for current availability and project or volume pricing.
Request a bulk quoteNeed cells for a production run or battery assembly? Include your model, quantity and destination when requesting a quote.
Technical information
Review the product information and manufacturer-related specifications below. Confirm the applicable datasheet and revision before engineering or procurement approval.
1. Rated Capacity
- Typical Capacity: 30Ah (achieved with 0.5C discharge after standard charge)
- Minimum Capacity: 29.5Ah
2. Nominal Voltage
- Voltage: 3.2V (mean operating voltage)
3. Voltage at End of Discharge
- Cut-off Voltage: 2.0V
4. Charging Voltage
- Voltage: 3.65V
5. Internal Impedance
- Resistance: ≤2mΩ (measured at AC 1kHz after 50% charge)
- Measurement Conditions: New batteries within one week of shipment and fewer than 5 cycles
6. Standard Charge
- Method: Constant current of 0.5C5A until 3.65V, then constant voltage until current drops to 0.05C5A
- Charge Time: Approximately 3.0 hours
7. Standard Discharge
- Method: Constant current of 0.5C5A until voltage drops to 2.0V
8. Fast Charge
- Method: Constant current of 1C5A until 3.65V, then constant voltage until current drops to 0.05C5A
- Charge Time: Approximately 1.5 hours
9. Fast Discharge
- Method: Constant current of 1C5A until voltage drops to 2.0V
10. Maximum Continuous Charge Current
- Current: 1.0C5A
11. Maximum Continuous Discharge Current
- Current: 2.0C5A (up to 3.0C5A for less than 10 seconds, with SOC ≥20%)
12. Operation Temperature Range
- Charging: 0 to 45°C
- Discharging: -20 to 55°C
- Humidity: 60±25% RH (bare cell)
13. Storage Temperature Range
- Less than 1 year: -10 to 30°C
- Less than 3 months: -10 to 40°C
- Humidity: 60±25% RH (at shipment state)
14. Battery Dimensions
- Thickness: 27.0±0.5mm
- Length: 180.0±1.0mm
- Width: 70.0±0.5mm
15. Battery Weight
- Weight: 690g±10g
This specification ensures the VP-LFP30 cell delivers reliable performance under specified conditions and is suitable for a wide range of applications.
Engineering and sourcing guide
Use the published product information and the applicable manufacturer datasheet to verify that this cell is suitable for the intended assembly. Specifications can differ by chemistry, cell format and manufacturer revision.
A loose cell is a component, not a finished battery system. Use it only within the manufacturer's stated limits and in an appropriately engineered assembly with suitable electrical, thermal, mechanical and protective measures. Do not infer safe operating limits from nominal capacity or voltage alone.
Frequently asked questions
Review the product details above and any datasheet linked in the product description. For engineering decisions, use the applicable manufacturer datasheet and confirm that its model and revision match the cell being quoted.
Yes. Use the Request a bulk quote link and include your required quantity, delivery destination and application. The product name and selected option are passed to the loose-cell quote page.
Share the exact cell model, required quantity, intended application, destination country, target delivery schedule and any documentation or compliance requirements.
No. A loose cell is a component. A finished battery system requires appropriate cell configuration, interconnection, enclosure, control and protection engineering for the intended application.